• Power Supply Unit Constant Current Source Vcsel Burn-in Testing Min Programmable Pulse Width 80us Source Measure Meter
  • Power Supply Unit Constant Current Source Vcsel Burn-in Testing Min Programmable Pulse Width 80us Source Measure Meter
  • Power Supply Unit Constant Current Source Vcsel Burn-in Testing Min Programmable Pulse Width 80us Source Measure Meter
  • Power Supply Unit Constant Current Source Vcsel Burn-in Testing Min Programmable Pulse Width 80us Source Measure Meter
  • Power Supply Unit Constant Current Source Vcsel Burn-in Testing Min Programmable Pulse Width 80us Source Measure Meter
  • Power Supply Unit Constant Current Source Vcsel Burn-in Testing Min Programmable Pulse Width 80us Source Measure Meter

Power Supply Unit Constant Current Source Vcsel Burn-in Testing Min Programmable Pulse Width 80us Source Measure Meter

After-sales Service: 1 Year
Function: Test
Display: Digital
Usage: Electric Component Tester, Gas Sensor Tester, Semiconductor Materials Test
Type: Electrolytic Capacitor Leakage Current Tester
Environment: Room Temperature
Customization:
Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
HCP200
Warranty
With Warranty
Power Source
AC 85V-265V
Weight
0-10Kg
Installation
Portable Precise
Customized
Customized
Transport Package
Carton Box
Specification
482*88*540mm
Trademark
Precise
Origin
China
HS Code
9030339000
Production Capacity
100PCS/Month

Product Description

power supply unit constant current source VCSEL burn-in testing min programmable pulse width 80us source measure meter    

Characteristics:
  • Characteristic test of nanomaterials: graphene, nanowires
  • Characteristic test of organic materials: electronic ink, printed electronic technology
  • Characteristic test of Energy and efficiency: LED/AMOLED, solar cells, battery, DC-DC converter
  • Characteristic test of discrete semiconductor devices: resistance, diode, light-emitting diode, Zener diode, PIN diode, BJT triode, MOSFET, SIC, etc.
  • Sensor test: resistivity, Hall effect
Power Supply Unit Constant Current Source Vcsel Burn-in Testing Min Programmable Pulse Width 80us Source Measure Meter


Technical Parameters:
 

Voltage accuracy: 
Voltage Source Measurement
Range Resolution Accuracy±(%rdg.+volts) Resolution Accuracy±(%rdg.+volts)
300mV 30uV 0.1%±300uV 30uV 0.1%±300uV
1V 100uV 0.1%±1mV 100uV 0.1%±1mV
3V 300uV 0.1%±2mV 300uV 0.1%±2mV
10V 1mV 0.1%±3mV 1mV 0.1%±3mV
30V 3mV 0.1%±5mV 3mV 0.1%±5mV
50V 5mV 0.1%±10mV 5mV 0.1%±10mV

Current accuracy:
Current Source Measurement
Range Resolution Accuracy±(%rdg.+volts) Resolution Accuracy±(%rdg.+volts)
100nA 10pA 0.1%±0.1nA 10pA 0.1%±0.1nA
1uA 100pA 0.1%±1nA 100pA 0.1%±1nA
10uA 1nA 0.1%±5nA 1nA 0.1%±5nA
100uA 10nA 0.1%±50nA 10nA 0.1%±50nA
1mA 100nA 0.1%±300nA 100nA 0.1%±300nA
10mA 1uA 0.1%±5uA 1uA 0.1%±5uA
100mA 10uA 0.1%±20uA 10uA 0.1%±20uA
1A 100uA 0.1%±2mA 100uA 0.1%±2mA
6A 600uA 0.1%±5mA 600uA 0.1%±5mA
10A 1mA 0.1%±10mA 1mA 0.1%±10mA
30A 3mA 0.1%±20mA 3mA 0.1%±20mA
50A 5mA 0.1%±50mA 5mA 0.1%±50mA
100A 10mA 0.1%±100mA 10mA 0.1%±100mA


DC max output power and source/sink limit:
Voltage Current
Max 300 W Max 300W
±10 V @ ±30.0 A ± 6.0A @ ± 50 V
±30 V @ ±10.0A ±10.0A @ ± 30V
±50V @ ±6.0A ± 30 A @ ± 10 V
four-quadrant output or input operation four-quadrant output or input operation

 Pulse max output power(source/sink):
max current limit max pulse width max duty ratio
6A@50V DC 100%
10A@30V DC 100%
30A@10V DC 100%
100A@50V 500uS 0.1%
50A@50V 3mS 1%
30A@50V 5ms 3%
10A@50V 20ms 10%
100A@30V 1mS 1%
50A@30V 5mS 3%
30A@30V 10ms 5%

Min programmable pulse width 80us
pulse programmable resolution 1us
pulse program accuracy ±5uS

 
source limit DC power max 300W,pulse power max 5000W,four-quadrant source/sink mode
overrange 105%range, source and measurement
stable load capacitance <22NF
broadband noise(20MHz) 30mV RMS(typical value),<100mV Vp-p (typical value)
FORCR HI and SENSE HI Max voltage difference 3V
FORCR LO and SENSE LOMax voltage difference 3V
output characteristics output impedance 1KΩ,output voltage offset<5mV
output cable characteristics Max impedance 15mΩ
max sampling rate 250000S/s
IO interface and trigger input/output IO,max voltage 5V,support external trigger, trigger polarity can be configured
communication interface  RS-232,GPIB,LAN
input power AC100-240V,  50/60Hz
working temperature 25±10ºC
size W 482mmxH 88mmxH 540mm
warranty 1 year

Pulsed Current Source  HCP series Working Quadrant Diagram
Power Supply Unit Constant Current Source Vcsel Burn-in Testing Min Programmable Pulse Width 80us Source Measure Meter
Power Supply Unit Constant Current Source Vcsel Burn-in Testing Min Programmable Pulse Width 80us Source Measure Meter
Power Supply Unit Constant Current Source Vcsel Burn-in Testing Min Programmable Pulse Width 80us Source Measure Meter
                         HCP100                                                                   HCP200                                                             HCP300



Factory
Power Supply Unit Constant Current Source Vcsel Burn-in Testing Min Programmable Pulse Width 80us Source Measure Meter
Power Supply Unit Constant Current Source Vcsel Burn-in Testing Min Programmable Pulse Width 80us Source Measure Meter


FQA:
1. Q:Precise is direct factory or trade company?
A: Precise is a factory, and all the SMU R&D are Precise team and manufactured by Precise.
 
2. Q:Sample order is available?
  A:Yes, we accept sample order.

3. Q:Do you supply software for SMU operation?
  A:Yes, we can design it as customer's requirement.
 
4. Q:whats the delivery period?
  A:usually, it is around 30 days, and it is also related with order qty.
 
5. Q:what's the warranty?
  A:warranty is 12 month.
 
6.Q: what's the shipping way?
  A:for sample order, usually shipping by international express like DHL, FEDEX, UPS, EMS and so on. If qty is more, by air is also a good choice.



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now