high current source pulsed source meter high power device reliability testing instument SMU
Characteristics:
- Characteristic test of nanomaterials: graphene, nanowires
- Characteristic test of organic materials: electronic ink, printed electronic technology
- Characteristic test of Energy and efficiency: LED/AMOLED, solar cells, battery, DC-DC converter
- Characteristic test of discrete semiconductor devices: resistance, diode, light-emitting diode, Zener diode, PIN diode, BJT triode, MOSFET, SIC, etc.
- Sensor test: resistivity, Hall effect
Technical Parameters:
Voltage accuracy:
Voltage |
Source |
Measurement |
Range |
Resolution |
Accuracy±(%rdg.+volts) |
Resolution |
Accuracy±(%rdg.+volts) |
300mV |
30uV |
0.1%±300uV |
30uV |
0.1%±300uV |
1V |
100uV |
0.1%±1mV |
100uV |
0.1%±1mV |
3V |
300uV |
0.1%±2mV |
300uV |
0.1%±2mV |
10V |
1mV |
0.1%±3mV |
1mV |
0.1%±3mV |
30V |
3mV |
0.1%±5mV |
3mV |
0.1%±5mV |
50V |
5mV |
0.1%±10mV |
5mV |
0.1%±10mV |
Current accuracy:
Current |
Source |
Measurement |
Range |
Resolution |
Accuracy±(%rdg.+volts) |
Resolution |
Accuracy±(%rdg.+volts) |
100nA |
10pA |
0.1%±0.1nA |
10pA |
0.1%±0.1nA |
1uA |
100pA |
0.1%±1nA |
100pA |
0.1%±1nA |
10uA |
1nA |
0.1%±5nA |
1nA |
0.1%±5nA |
100uA |
10nA |
0.1%±50nA |
10nA |
0.1%±50nA |
1mA |
100nA |
0.1%±300nA |
100nA |
0.1%±300nA |
10mA |
1uA |
0.1%±5uA |
1uA |
0.1%±5uA |
100mA |
10uA |
0.1%±20uA |
10uA |
0.1%±20uA |
1A |
100uA |
0.1%±2mA |
100uA |
0.1%±2mA |
6A |
600uA |
0.1%±5mA |
600uA |
0.1%±5mA |
10A |
1mA |
0.1%±10mA |
1mA |
0.1%±10mA |
30A |
3mA |
0.1%±20mA |
3mA |
0.1%±20mA |
50A |
5mA |
0.1%±50mA |
5mA |
0.1%±50mA |
100A |
10mA |
0.1%±100mA |
10mA |
0.1%±100mA |
DC max output power and source/sink limit:
Voltage |
Current |
Max 300 W |
Max 300W |
±10 V @ ±30.0 A |
± 6.0A @ ± 50 V |
±30 V @ ±10.0A |
±10.0A @ ± 30V |
±50V @ ±6.0A |
± 30 A @ ± 10 V |
four-quadrant output or input operation |
four-quadrant output or input operation |
Pulse max output power(source/sink):
max current limit |
max pulse width |
max duty ratio |
6A@50V |
DC |
100% |
10A@30V |
DC |
100% |
30A@10V |
DC |
100% |
100A@50V |
500uS |
0.1% |
50A@50V |
3mS |
1% |
30A@50V |
5ms |
3% |
10A@50V |
20ms |
10% |
100A@30V |
1mS |
1% |
50A@30V |
5mS |
3% |
30A@30V |
10ms |
5% |
Min programmable pulse width 80us
pulse programmable resolution 1us
pulse program accuracy ±5uS
source limit |
DC power max 300W,pulse power max 5000W,four-quadrant source/sink mode |
overrange |
105%range, source and measurement |
stable load capacitance |
<22NF |
broadband noise(20MHz) |
30mV RMS(typical value),<100mV Vp-p (typical value) |
FORCR HI and SENSE HI Max voltage difference |
3V |
FORCR LO and SENSE LOMax voltage difference |
3V |
output characteristics |
output impedance 1KΩ,output voltage offset<5mV |
output cable characteristics |
Max impedance 15mΩ |
max sampling rate |
250000S/s |
IO interface and trigger |
input/output IO,max voltage 5V,support external trigger, trigger polarity can be configured |
communication interface |
RS-232,GPIB,LAN |
input power |
AC100-240V, 50/60Hz |
working temperature |
25±10ºC |
size |
W 482mmxH 88mmxH 540mm |
warranty |
1 year |
Pulsed Current Source HCP series Working Quadrant Diagram
HCP100 HCP200 HCP300
Factory
FQA:
1. Q:Precise is direct factory or trade company?
A: Precise is a factory, and all the SMU R&D are Precise team and manufactured by Precise.
2. Q:Sample order is available?
A:Yes, we accept sample order.
3. Q:Do you supply software for SMU operation?
A:Yes, we can design it as customer's requirement.
4. Q:whats the delivery period?
A:usually, it is around 30 days, and it is also related with order qty.
5. Q:what's the warranty?
A:warranty is 12 month.
6.Q: what's the shipping way?
A:for sample order, usually shipping by international express like DHL, FEDEX, UPS, EMS and so on. If qty is more, by air is also a good choice.